linux [2020/07/14 17:58] – [Cisco Catalyst 2950-48 Configuration] philiplinux [2020/07/14 18:00] (current) – [Cisco Catalyst 2950-48 Configuration] philip
Line 93: Line 93:
 </code> </code>
  
-==== Cisco Catalyst 2950-48 Configuration ====+==== Cisco Catalyst 2950G-48 Configuration ====
  
-Configuration snipped for a Catalyst 2950-48 running '12.1(22)EA13'. Note that the 2950-48 needs the ''flowcontrol send off'' command - other switches don't seem to need this.+Configuration snipped for a Catalyst 2950G-48 running '12.1(22)EA13'. Note that the 2950G-48 needs the ''flowcontrol send off'' command - other switches don't seem to need this.
  
 For security reasons, I've made the native VLAN on the trunk to be 999, rather than the default VLAN of 1. I strongly recommend never to use VLAN1 for anything. For security reasons, I've made the native VLAN on the trunk to be 999, rather than the default VLAN of 1. I strongly recommend never to use VLAN1 for anything.
Line 122: Line 122:
 ! !
 </code> </code>
 +
 +With this configuration, VLAN 999 is the native VLAN (frames sent untagged), and all other VLANs (including 1) are sent tagged.
  